Hazardous materials store WHG 360
Item number: 274685W
- Approved for storage of water-polluting and flammable substances.
- Enclosed construction with walls and roof in corrosion resistant galvanised and painted profile sheets (RAL 5010, gentian blue).
- Water law tested, one piece 5 mm spill pallet with easily removable hot dip galvanised grids (max. load capacity: 1,000 kg/m²).
- Low entry height of 150 mm.
- 2-wing door (with safety lock) on the long side of the room.
- Delivered ready assembled.
- Crane eyes as standard for safe transport to the installation site
- Natural ventilation available on request.
Structural analysis
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Guidelines for storing flammable liquids (flash point ≤ 60 ° C, classes H226, H225 and H224)
- Observe distance from fire loads (mostly min. 10 m)
- Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
- Country-specific requirements for air exchange rate
- Specifications in accordance with HSG71
- Specifications in accordance with ATEX Directive 2014/34/EU
Product information
| Technical data | Details |
|---|---|
| Dimensions (without attachments) W x D x H [mm] | 6028 x 2800 x 2235 |
| Internal dimensions W x D x H [mm] | 5830 x 2590 x 2000 |
| Model (external dimensions W X D) | WHG 360 (6028 x 2800 mm) |
| Storage area [m²] | 15 |
| Containment volume [l] | 2224 |
| Colour | Gentian violet |
| RAL Code | 5010 |
| Weight [kg] | 1860 |
| Load capacity [kg/m²] | 1000 |
- Approved for storage of water-polluting and flammable substances.
- Enclosed construction with walls and roof in corrosion resistant galvanised and painted profile sheets (RAL 5010, gentian blue).
- Water law tested, one piece 5 mm spill pallet with easily removable hot dip galvanised grids (max. load capacity: 1,000 kg/m²).
- Low entry height of 150 mm.
- 2-wing door (with safety lock) on the long side of the room.
- Delivered ready assembled.
- Crane eyes as standard for safe transport to the installation site
- Natural ventilation available on request.
Structural analysis
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Guidelines for storing flammable liquids (flash point ≤ 60 ° C, classes H226, H225 and H224)
- Observe distance from fire loads (mostly min. 10 m)
- Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
- Country-specific requirements for air exchange rate
- Specifications in accordance with HSG71
- Specifications in accordance with ATEX Directive 2014/34/EU
-
DIBt
Service
Matching accessories and spare parts
Customer reviews
to Mainland U.K.
by our hazmat experts
in accordance with the terms and conditions
directly from the manufacturer