Fire-rated storage container RFP 815.30 SD

Item number: 274741W

  • Best option when larger quantities of hazardous materials need to be stored in a separate fire compartment and no clearance is available.
  • The larger sliding doors offer up to 50 % more storage capacity.
  • An open sliding door gives easier access to the fire-rated storage container with shelving than a wing door and improves logistical efficiency; when installed outdoors, there is no risk of the doors slamming shut unintentionally due to wind loads.
  • The manually or electrically operated fire-rated doors, tested according to EN 16034, close automatically when the fire detectors are triggered.
  • Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area, e.g. in a production hall. Exception: peroxide stores.
  • Base: tested, single-piece spill pallet with easily removable hot-dip galvanised grids.
  • Water law tested, two piece, hot dip galvanised 5 mm spill pallet in the lower storage level, with removable grids (max. load capacity: 1,250 kg/m²).
  • Long-lasting corrosion protection with fully-galvanised base material and high-quality 2K paint (RAL 9002, grey-white).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Storage surfaces fitted with removable, hot-dip galvanised grids.
  • Shelf guards on the rear wall.
  • Galvanised components with two layers of paint give long lasting corrosion protection, support frame made of hot dip galvanised base material.
  • Equipotential bonding with earthing through the steel frame construction.
  • Points to consider when storing flammable materials: equipotential bonding / earthing and technical ventilation.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m².

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Prerequisites for storing flammable liquids

(Flashpoint ≤ 60 °C, classified as H226, H225 or H224)

  • Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
  • Country-specific requirements for air exchange rate
  • Specifications in accordance with HSG71
  • Specifications in accordance with ATEX Directive 2014/34/EU
Full description

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Best option when larger quantities of hazardous materials need to be stored in a separate fire compartment and no clearance is available.
  • The larger sliding doors offer up to 50 % more storage capacity.
  • An open sliding door gives easier access to the fire-rated storage container with shelving than a wing door and improves logistical efficiency; when installed outdoors, there is no risk of the doors slamming shut unintentionally due to wind loads.
  • The manually or electrically operated fire-rated doors, tested according to EN 16034, close automatically when the fire detectors are triggered.
  • Install directly next to the external wall of neighbouring buildings or as a fire-rated separate area, e.g. in a production hall. Exception: peroxide stores.
  • Base: tested, single-piece spill pallet with easily removable hot-dip galvanised grids.
  • Water law tested, two piece, hot dip galvanised 5 mm spill pallet in the lower storage level, with removable grids (max. load capacity: 1,250 kg/m²).
  • Long-lasting corrosion protection with fully-galvanised base material and high-quality 2K paint (RAL 9002, grey-white).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Storage surfaces fitted with removable, hot-dip galvanised grids.
  • Shelf guards on the rear wall.
  • Galvanised components with two layers of paint give long lasting corrosion protection, support frame made of hot dip galvanised base material.
  • Equipotential bonding with earthing through the steel frame construction.
  • Points to consider when storing flammable materials: equipotential bonding / earthing and technical ventilation.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m².

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Prerequisites for storing flammable liquids

(Flashpoint ≤ 60 °C, classified as H226, H225 or H224)

  • Create equipotential bonding (earthing) (connection point provided); if required provide lightning protection
  • Country-specific requirements for air exchange rate
  • Specifications in accordance with HSG71
  • Specifications in accordance with ATEX Directive 2014/34/EU

Quality features

Technical data

Model RFP 815.30 SD
Dimensions (without attachments) W x D x H [mm] 9410 x 2238 x 3594
Bay dimensions W x D x H [mm] 3900 x 1440 x 1300
Load capacity [kg/m²] 1250
Containment volume [l] 2 x 1720
Colour Grey white
RAL Code 9002
Capacity IBC / CP / EP / drum 12 / 12 / 16 / 48
Number of storage levels 2
Weight [kg] 7780

Documents

Service for the product

Do you need help?
We work hard to give you good advice.
Free Expert Advice 01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Menu
Log in
Your basketAdded to basket
Go to basket
We would be pleased to provide you with advice!

Give us a call or fill out the form and we will get back to you as soon as possible.

Mon - Thu: 08:30 - 17:00 | Fri: 08:30 - 16:00